Using a combination of automated diffraction tomography and precession electron diffraction techniques, quasi-kinematical electron diffraction data sets were collected from intermetallic Ni1+xTe1 embedded nanodomains and ion-thinned specimens of 6H–SiC semiconductor. Cell parameters and space groups were found automatically from the reconstructed 3D diffraction volume. The extracted intensities were used for fast ab initio structure determination by direct methods.